A zinc coating class is the total zinc mass in g/m² on both surfaces of the coil. The export ladder: Z80 (dry indoor) → Z120 (general indoor) → Z180 (semi-exposed) → Z275 (the outdoor default for roofing and cladding) → Z450 (coastal and aggressive service). 1 µm of zinc ≈ 7.1 g/m² per side, so Z275 ≈ 19 µm per side. PPGI is paint over one of these same classes — the Z number matters even under color.
Ordering GI coil by writing just "galvanized" is like ordering steel by writing "metal". The zinc coating class — the Z number — is the single specification that decides how long the coil survives where you put it, and it is the first line of any serious spec. This page compares the five classes that cover almost every export order — Z80, Z120, Z180, Z275 and Z450 — with the gram-to-micron conversion, the applications each class belongs in, and a checklist that catches the quiet downgrades.
What the Z number actually means
The class is a mass, not a thickness: the total zinc deposited on both surfaces, in grams per square metre of sheet. Z120 = 120 g/m²; Z275 = 275 g/m². Mills measure and certify mass, zinc is traded by weight, and you are invoiced for it — so the standard speaks grams first.
The product standards behind the letters: EN 10346 defines the Z-class ladder for continuously hot-dip coated steel, ASTM A653 orders the same coatings by "G" grades, and JIS G3302 uses two-digit codes. They all express the same physical thing — zinc mass on steel — so a Z-class call-out translates across systems (table below).
Two details trip up first-time buyers. First, the standard controls the total for both surfaces; thickness figures assume the mill splits it roughly 50/50 between front and back, which is normal practice. Second, the class says nothing about the steel underneath — a formable DX51D+Z bending grade and a structural S350GD can both carry Z275. Base-grade selection is a separate decision (see our DX51D decoder).
g/m² to µm: the conversion
Zinc density is 7.14 g/cm³, so 1 µm of zinc ≈ 7.1 g/m² per surface. Because classes quote the two-sides total:
µm per side ≈ class ÷ 2 ÷ 7.1 → Z275: 275 ÷ 2 ÷ 7.1 ≈ 19 µm
For weights rather than thickness — how many kilograms the zinc layer adds to a sheet or a full coil — use our galvanizing weight calculator. On 0.5 mm sheet, Z275 zinc is about 6.5% of total weight; on 1.0 mm, about 3.4%. That share is real money at tonnage, which is why the weight-basis check below exists.
The five classes compared
| Class | Total zinc (g/m²) | ≈ µm per side | ASTM A653 equivalent | JIS G3302 equivalent | Typical duty |
|---|---|---|---|---|---|
| Z80 | 80 | 5.6 | below G30 (special class) | — | Dry indoor, furniture, ducting |
| Z120 | 120 | 8 | G40 | Z12 | General indoor, panel base |
| Z180 | 180 | 13 | G60 | Z18 | Semi-exposed, PPGI base |
| Z275 | 275 | 19 | G90 | Z27 (270) | Outdoor roofing default |
| Z450 | 450 | 32 | — (order to EN 10346) | Z45 | Coastal, livestock, heavy industry |
Conversion notes: ASTM A653 grades are in oz/ft² total both sides — 1 oz/ft² = 305 g/m² — so G40 ≈ Z120, G60 ≈ Z180 and G90 ≈ Z275. Z80 sits below the common A653 minimum (G30 ≈ 92 g/m²), so US-spec buyers either step up to that class or call Z80 out as a special. The full EN 10346 ladder also includes Z100, Z140, Z200, Z225 and Z350 between the five headline classes; mills roll them by agreement where a project wants fine control.
Class by class in practice
Z80 — the dry-indoor economy class
About 5.6 µm per side. Made for environments that never see condensation: furniture frames, appliance internal parts, air ducting, cable trunking, and coil that gets painted immediately in a factory line, where the paint carries the duty. At this thickness a small coating miss is a large percentage miss, so Z80 is exactly where the certificate check in the checklist earns its keep.
Z120 — the general-indoor workhorse
About 8 µm per side. The default for interior construction steel: purlin and C/Z profiles inside the building envelope, racking, appliance cabinets, trunking and general fabrication. It is also the standard base under PPGI for panel and appliance production (see PPGI for sandwich panels). Z120 survives site exposure for weeks during construction, but it is not a final outdoor surface.
Z180 — semi-exposed and the popular PPGI base
About 13 µm per side. The bridge class: soffits and parapets, shed interiors with humidity, agricultural building steel, fence components, and the coil many panel makers prefer because it balances cost against edge protection after roll-forming. Where a project is inland but only sheltered rather than sealed, Z180 is usually the right call.
Z275 — the outdoor default
About 19 µm per side. The class export construction runs on: bare GI roofing and wall cladding (sizes and profiles in our GI roofing sheet guide), purlin lines exposed during construction (see C and Z purlins), solar mounting rails, and the coil stockists carry across the board in 0.4–2.0 mm. It is the sweet spot of price-per-gram of protection; for the full specification decode, see our Z275 galvanized coil guide.
Z450 — heavy exposure
About 32 µm per side. For coastal sites, heavy-industrial air, and livestock and poultry buildings where humidity and ammonia eat thin coatings: silos, culvert, drainage, long maintenance-free targets. Trade-offs to spec knowingly: more zinc means more cost per tonne, thick layers can powder at tight roll-forming radii, and welding over heavy zinc needs more parameter care. Above Z450, continuous coating hands over to batch hot-dip galvanizing after fabrication (a different system — decoded in ASTM A123 hot-dip galvanizing) or to aluzinc.
Choosing by environment
Zinc corrodes at a roughly steady rate in any given atmosphere, which makes the class a life dial: in the same environment, roughly doubling the zinc roughly doubles the time to first rust. Indicative bands for bare GI inland:
| Atmosphere / duty | Class | Indicative bare life |
|---|---|---|
| Dry indoor, painted over | Z80–Z120 | 5–10+ years (interior duty) |
| Sheltered, light exposure | Z180 | 10–15 years |
| Outdoor inland — roofing, cladding | Z275 | 15–25 years |
| Coastal, industrial, livestock | Z350–Z450 or GL | 30+ years |
Two caveats. Environment dominates: chloride near the coast or industrial fallout beats any class on paper, so a coastal project should move up the ladder or switch to aluzinc GL — the comparison lives in our GI vs GL vs aluzinc vs PPGI guide. And transit white rust is a packing failure, not an atmosphere problem — it scars any class equally.
GI, PPGI and the class under the paint
PPGI is not a competing coating — it is paint over GI. The order code still carries the zinc class under the topcoat, e.g. "0.5 mm DX51D+Z Z180, PE 15 µm RAL 3005". The zinc protects what paint cannot reach: cut edges after roll-forming, scratches during installation, and fastener holes. A beautiful paint system on a thin zinc base still rusts at every cut edge.
Practice by product: sandwich-panel and appliance lines build on Z120–Z180, which the paint then finishes; exposed roofing in ordinary climates is ordered Z275 even under paint; severe sites go higher. The paint system itself (PE, SMP, HDP, PVDF) is a separate decision about color and gloss retention — that ladder is in our PPGI coating guide, and the bare-vs-painted trade-off in GI vs PPGI.
The GI coil buying checklist
- Call the class explicitly. Write "GI coil, SGCC, Z120 g/m²" — never "galvanized coil" alone. The Z number is the specification.
- Fix the base grade separately. DX51D+Z for forming, S350GD for structural, SGCC for the classic Japanese-spec twin — the class does not tell you which one you got.
- Define average vs single-spot. Product standards set both a mean requirement and a lower single-spot minimum for the same class; state which governs acceptance, and at what rejection threshold.
- Require coating results on the MTC. Gauge or dissolution values per coil, on the EN 10204 3.1 certificate with matching heat numbers — how to read one is in our mill test certificate guide.
- Agree the weight basis. The zinc is part of the invoiced coil weight — 6.5% of total at Z275 on 0.5 mm — so confirm whether competing quotes are on total weight or base steel before comparing anything (per-coil math: GI coil weight calculator).
- Protect it in transit. Passivation plus dry packing for sea freight; white rust is cosmetic but it is the most common claim on arrival, and the inspection points are in our QC inspection checklist.
FAQ
What do zinc coating classes Z80, Z120, Z180 and Z275 mean?
The number is the total zinc mass in g/m² on both surfaces combined. Z120 means 120 g/m², about 8 µm per side; Z275 means 275 g/m², about 19 µm per side — the standard outdoor class for roofing and cladding.
How thick is Z275 in microns?
About 19 µm per side: 275 ÷ 2 ÷ 7.1, using 1 µm of zinc ≈ 7.1 g/m² per surface (zinc density 7.14 g/cm³). Coating classes quote the total for both sides, so divide by two before converting to thickness.
Which zinc coating class should I use for outdoor roofing?
Z275 is the default for bare GI roofing and cladding. In coastal or heavy-industrial air, step up to Z350–Z450 or use aluzinc (GL, AZ150). Z120–Z180 is for indoor, painted-over or sheltered duty.
Does PPGI still need a zinc coating class?
Yes. PPGI is paint over a GI base, and the zinc class underneath protects cut edges, scratches and fastener holes that paint cannot. Panel production typically builds on Z120–Z180; exposed roofing coils on Z275.
How is a zinc coating class verified?
By magnetic gauge or dissolution test per the product standard (EN 10346 / ASTM A653), reported on the mill test certificate. Specify average and single-spot requirements, and check the values before you pay.
GI coil Z80–Z450 — send width, thickness, class, tonnage
Send your coil specification to [email protected] or WhatsApp +86 191 5745 8011 — width × thickness × class × tonnage. EXW/FOB shipping, coating test results on the MTC with every order.
Request GI Coil QuoteRelated: GI Coil product page · Z275 galvanized coil · Galvanizing weight calculator · GI coil meters per ton · GI vs PPGI · GI vs GL vs aluzinc guide
Last updated: November 2026. Coating values per EN 10346 / ASTM A653 / JIS G3302; verify actual values on the MTC for each coil.