H beam weight per meter is set by the section, not the grade: HN 300×150 = 37.3 kg/m, HM 294×200 = 57.3 kg/m, HN 400×200 = 66.0 kg/m, HW 300×300 = 94.5 kg/m. Tables below cover HW 100×100–400×400, HM 148×100–588×300 and HN 150×75–900×300 per GB/T 11263. For any size not listed: kg/m = [(h − 2·tf) × tw + 2 × b × tf] × 0.00785.
This H beam weight chart in kg lists the theoretical weight per meter of the HW, HM and HN sections that actually move in international trade — the sizes you will be quoted on from Chinese rolling programs. GB/T 11263 and JIS G3192 share the same geometry, so one chart covers Q235B/Q355B call-outs and SS400/SM490 call-outs alike.
Buyers use kg/m for four jobs: turning a bill of materials into tonnage, sanity-checking a supplier's quote, planning containers, and comparing sections before design freeze. Weight is also where most commercial surprises live — theoretical vs weighed billing can shift an invoice by a few percent — so the tables come with the formula and the checks that keep the number honest.
How to read the tables
Every designation carries four dimensions in millimetres: height × flange width × web thickness × flange thickness. HN 400×200×8×13 is 400 mm deep, 200 mm wide across the flange, with an 8 mm web and 13 mm flanges.
- HW (wide flange): flange width ≈ section height — the column family. Heavy, stable, best in compression.
- HM (middle flange): intermediate proportions — girders, transfer beams, general framing.
- HN (narrow flange): deep and slim — the beam family, like IPE, efficient in one-direction bending.
The full designation system, including how HW/HM/HN map to ASTM W and EN IPE/HEA/HEB, is decoded in our GB H beam guide. One rule worth repeating here: the steel grade does not change weight. Q235B, Q355B, SS400, SM490, A36 and A572 Gr50 beams of the same size weigh exactly the same — the grade changes mechanical properties only.
HW weight chart (wide flange — columns)
| Designation | Section h×b×tw×tf (mm) | Weight (kg/m) | kg per 12 m piece |
|---|---|---|---|
| HW 100×100 | 100×100×6×8 | 17.2 | 206 |
| HW 125×125 | 125×125×6.5×9 | 23.8 | 286 |
| HW 150×150 | 150×150×7×10 | 31.9 | 383 |
| HW 175×175 | 175×175×7.5×11 | 40.4 | 485 |
| HW 200×200 | 200×200×8×12 | 50.5 | 606 |
| HW 250×250 | 250×250×9×14 | 72.4 | 869 |
| HW 300×300 | 300×300×10×15 | 94.5 | 1,134 |
| HW 350×350 | 350×350×12×19 | 137 | 1,644 |
| HW 400×400 | 400×400×13×21 | 172 | 2,064 |
Heavy-flange twins of the same depths exist and ship regularly: HW 200×204×12×12 = 56.7, HW 250×255×14×14 = 82.2, HW 300×305×15×15 = 106, HW 400×408×21×21 = 197, HW 414×405×18×28 = 233 and HW 428×407×20×35 = 284 kg/m. If your drawing calls the deep end of this range, it is likely a column or driven pile job — see H pile foundations.
HM weight chart (middle flange — girders and framing)
| Designation | Section h×b×tw×tf (mm) | Weight (kg/m) | kg per 12 m piece |
|---|---|---|---|
| HM 148×100 | 148×100×6×9 | 21.4 | 257 |
| HM 194×150 | 194×150×6×9 | 31.2 | 374 |
| HM 244×175 | 244×175×7×11 | 44.1 | 529 |
| HM 294×200 | 294×200×8×12 | 57.3 | 688 |
| HM 340×250 | 340×250×9×14 | 79.7 | 956 |
| HM 390×300 | 390×300×10×16 | 107 | 1,284 |
| HM 440×300 | 440×300×11×18 | 124 | 1,488 |
| HM 482×300 | 482×300×11×15 | 115 | 1,380 |
| HM 488×300 | 488×300×11×18 | 129 | 1,548 |
| HM 582×300 | 582×300×12×17 | 137 | 1,644 |
| HM 588×300 | 588×300×12×20 | 151 | 1,812 |
At each depth from 480 mm up, mills roll a light and a heavy variant (482 vs 488, 582 vs 588) — same height, thicker flange. The tonnage difference is 10–15%, so confirm which one the drawing means before you accept a "same size" substitution.
HN weight chart (narrow flange — beams)
| Designation | Section h×b×tw×tf (mm) | Weight (kg/m) | kg per 12 m piece |
|---|---|---|---|
| HN 150×75 | 150×75×5×7 | 14.3 | 172 |
| HN 198×99 | 198×99×4.5×7 | 18.5 | 222 |
| HN 200×100 | 200×100×5.5×8 | 21.7 | 260 |
| HN 248×124 | 248×124×5×8 | 25.8 | 310 |
| HN 250×125 | 250×125×6×9 | 29.7 | 356 |
| HN 298×149 | 298×149×5.5×8 | 32.6 | 391 |
| HN 300×150 | 300×150×6.5×9 | 37.3 | 448 |
| HN 346×174 | 346×174×6×9 | 41.8 | 502 |
| HN 350×175 | 350×175×7×11 | 50.0 | 600 |
| HN 396×199 | 396×199×7×11 | 56.7 | 680 |
| HN 400×200 | 400×200×8×13 | 66.0 | 792 |
| HN 446×199 | 446×199×8×12 | 66.7 | 800 |
| HN 450×200 | 450×200×9×14 | 76.5 | 918 |
| HN 496×199 | 496×199×9×14 | 79.5 | 954 |
| HN 500×200 | 500×200×10×16 | 89.6 | 1,075 |
| HN 596×199 | 596×199×10×15 | 95.1 | 1,141 |
| HN 600×200 | 600×200×11×17 | 106 | 1,272 |
| HN 700×300 | 700×300×13×24 | 185 | 2,220 |
| HN 800×300 | 800×300×14×26 | 210 | 2,520 |
| HN 900×300 | 900×300×16×28 | 243 | 2,916 |
The odd-looking heights are the light-gauge twins of each round size: 198×99, 248×124, 298×149, 346×174, 396×199, 446×199, 496×199 and 596×199 sit next to their 200, 250, 300, 350, 400, 450, 500 and 600 counterparts. Both are standard — check which one your drawing means, because the weight gap runs 10–15% within the same nominal depth. HN 400×200 and HN 300×150 are the two most-traded beam sizes we ship; the JIS call-outs for the same geometry are covered in JIS G3192 H beams.
The weight formula behind every number
Steel weighs 7.85 g/cm³, so kilograms per meter = cross-section area in mm² × 0.00785. For an H section, area comes from three rectangles:
area ≈ (h − 2·tf) × tw + 2 × b × tf → kg/m = area × 0.00785
Worked example, HN 400×200×8×13: web = (400 − 26) × 8 = 2,992 mm²; flanges = 2 × 200 × 13 = 5,200 mm²; total = 8,192 mm² → 8,192 × 0.00785 = 64.3 kg/m. The published standard value is 66.0 kg/m — the 1–3% gap is the root fillets at the web-flange junction, which standard tables include and the formula ignores. Use the formula for custom and asymmetric sections and for quick checks; use the standard tables in procurement documents.
From kg/m to order tonnage
Three conversions cover almost every commercial question:
- Total order weight = kg/m × piece length (m) × number of pieces. Example: 60 pcs of HN 400×200 × 12 m = 66.0 × 12 × 60 = 47,520 kg ≈ 47.5 t — about two 40 ft containers of bundled beams.
- Meters per ton = 1000 ÷ kg/m. HN 400×200 → 15.2 m per ton; HW 300×300 → 10.6; HN 300×150 → 26.8; HW 250×250 → 13.8.
- Piece weight = kg/m × length. The 12 m column in the tables is this line, done — because 12 m is the common mill length for export.
To avoid doing this by hand per size, our H beam weight calculator runs the same numbers interactively (GB, ASTM W, IPE and HEA/HEB series, length and piece count), and the container payload and packing rules live in shipping steel from China.
Matching these sizes to W, IPE and HEB
If your drawings are in ASTM or EN sections, the GB families map across cleanly — nearest matches by weight class:
| GB section | kg/m | Nearest ASTM W | Nearest EN | Typical use |
|---|---|---|---|---|
| HN 300×150 | 37.3 | W12×26 (38.7 kg/m) | IPE 300 (42.2 kg/m) | Floor beams |
| HM 294×200 | 57.3 | W14×60-class | between IPE 400/450 | Girders |
| HW 250×250 | 72.4 | W10×88-class | HEB 260-class | Columns |
| HW 300×300 | 94.5 | W12×120-class | HEB 300-class | Heavy columns |
In the W series the second number is pounds per foot by definition: kg/m = lb/ft × 1.488. Full W-series conversions are in our W beam size chart, the flange-geometry trade-offs in H beam vs I beam, and the tapered-flange Chinese I beam in GB I beam sizes.
Theoretical vs actual weight — the billing trap
The numbers in these tables are theoretical weights: calculated from the standard section. The steel that arrives on the truck is weighed, and actual weighbridge figures typically land within ±2–4% of theoretical. Mills roll within tolerance, so a ton of "HN 400×200" can be a few percent more or less steel than the table says.
That gap becomes money when the invoice is written. Some suppliers bill on theoretical weight, some on actual — and a quote that looks thin can be the one billing the heavier basis. Fix three things in writing before the PI is signed: the billing basis (theoretical or weighed), the allowed tolerance, and what evidence ships with the order. A serious supplier sends weighbridge tickets and an EN 10204 3.1 mill certificate per heat — the verification steps are listed in our pre-shipment inspection checklist, and how Chinese beam quotes are built (base, processing, weight basis) is unpacked in our quote-structure guide.
H beam buying checklist
- Write the full call-out: family + h×b×tw×tf + grade + length. "H beam 300" is not a size — HW 300×300 (94.5 kg/m) and HN 300×150 (37.3) differ by a factor of 2.5.
- Name the standard: GB/T 11263 or JIS G3192 (same geometry) — it fixes the tolerance regime the section is rolled and accepted under.
- Pick the grade as a design decision: Q235B/Q355B, SS400/SM490, or ASTM A36/A572 Gr50 per the drawing — same weight, different properties. Equivalences are cross-referenced in our GB equivalents guide.
- Fix lengths early: 6/9/12 m move fastest from stock; custom cut-to-length adds processing days.
- Fix the billing basis and tolerance (theoretical vs weighbridge, ±%) before comparing any two quotes.
- Require the EN 10204 3.1 MTC with heat numbers matching the stencils, plus weighbridge tickets at loading.
- State the surface: black, primed, or galvanized. Hot-dip galvanizing after fabrication adds a few percent to member weight and is a different coating system from mill pre-galvanizing — decoded in ASTM A123 hot-dip galvanizing.
FAQ
How much does an H beam weigh per meter?
Weight per metre depends on the section, not the grade. Common GB/T 11263 values: HN 300×150 = 37.3 kg/m, HM 294×200 = 57.3 kg/m, HN 400×200 = 66.0 kg/m, HW 300×300 = 94.5 kg/m. The tables above cover HW 100×100–400×400 and HN 150×75–900×300.
What do HW, HM and HN mean on H beams?
They are the three families of GB/T 11263: HW (wide flange, width about equal to height) is the column family, HM (middle flange) suits girders and general framing, HN (narrow flange) is the beam family, like IPE. JIS G3192 sections share the same geometry, so the chart covers SS400 and SM490 call-outs too.
How do you calculate H beam weight without a table?
Cross-section area is about (h − 2·tf) × tw + 2 × b × tf in mm²; then kg/m = area × 0.00785. For HN 400×200×8×13: (400−26)×8 + 2×200×13 = 8,192 mm², so 64.3 kg/m. Published standard values run about 1–3% higher because they include root fillets.
Is theoretical weight the same as actual weight?
No. Theoretical weight is the standard's calculated value; actual weighbridge weight is typically within ±2–4% of it. Before ordering, fix in writing whether billing is on theoretical or weighed weight and what tolerance applies.
Does the steel grade change H beam weight?
No. Q235B, Q355B, SS400, SM490, A36 and A572 Gr50 beams of the same size weigh the same — the grade changes mechanical properties, not kg/m. Grade selection is a design decision; weight comes from the section.
Send your HW/HM/HN size list — get exact weights and piece counts
Send sizes (h×b×tw×tf), lengths and pieces to [email protected] or WhatsApp +86 191 5745 8011. We reply with theoretical and actual weights, container plan, and an EN 10204 3.1 mill certificate with every order.
Request H Beam QuoteRelated: H Beam product page · H beam size chart · GB H beam (HW/HM/HN) guide · Weight calculator · Full GB weight table (I beam, channel, angle) · SS400 H beam · C channel weight chart
Last updated: November 2026. Weights are theoretical per GB/T 11263 / JIS G3192; billing basis per order confirmation.